How Y1/Y2 Dual-Axis Synchronization Works in a Servo Electric Press Brake
By Author: Mark Hanks
The ram on a dual-drive press brake is driven by two independent drive mechanisms. Although each side receives the same position command, slight differences in loading, mechanical resistance and drive response can cause position errors on the two ends of the ram, affecting ram parallelism.
Y1/Y2 synchronization addresses this problem. The controller monitors the position feedback of both ends of the ram and determines whether each axis follows its commanded trajectory. In addition, the controller monitors the error between the two axes and coordinates the position of each axis. The control system adjusts each drive output to reduce position errors between the two sides of the ram. Synchronization control operates throughout rapid approach, bending, deceleration and return.
What Y1 and Y2 Actually Mean
More precisely, Y1 and Y2 denote the controlled positions on the left and right sides of the ram, respectively. Each position axis is made up of a servo drive, servo motor, mechanical transmission, and position feedback. The position of the corresponding side of the ram is the controlled variable.
In a dual-servo motor, dual-ball screw configuration, the left servo motor drives one end of the ram via a reduction mechanism, coupling and ball screw, while the right servo motor drives the other end via a similar arrangement. Since both driving mechanisms act on the same ram, the objective of position control, in addition to positioning Y1 and Y2 to their respective target positions, is to restrict the differential position of the two sides throughout the entire cycle of movement to maintain the parallelism of the ram.
It should be noted that there are many temporary errors that may occur during the movement of the ram, and may cause the ram to be not entirely parallel while moving. Even if the ram ultimately arrives in its commanded position, temporary deviation during movement may increase the mechanical impact loads, and/or may trigger the system’s synchronization protection.
The Closed-Loop Signal Path
A basic description of a dual-axis closed-loop position control system is as follows:
1.Trajectory Generation: A CNC system creates ram position and motion trajectory commands.
2. Command Transmission: The motion controller sends these commands to the left and right servo drives.
3. Mechanical Actuation: The two servo motors drive their corresponding sides of the ram through the mechanical transmission.
4. Position Feedback: The actual position of axes Y1 and Y2 is provided by respective position sensors.
5. Closed-loop Error Correction: The controller continuously adjusts the servo drive outputs, based on the feedback, so that the axis tracking errors and Y1/Y2 synchronization error remain within the machine’s specified limits.

Two error measures are relevant to Y1/Y2 synchronization. Assuming both axes use a common coordinate direction and position datum, and the commanded reference position is Yref and actual positions of left and right sides are Y1 and Y2 respectively, the tracking error for either axis is expressed as Yref - Y1 and Yref - Y2 respectively. The synchronization error of the two axes is expressed as Y1 - Y2.
Sign of the synchronization error shows which side is leading in the defined coordinate system and the absolute value shows the difference in position of the two sides.
Tracking error answers the question: "Is each axis following its commanded trajectory?" Synchronization error answers a different question: "Are the two sides maintaining coordinated movement?" A dual-drive electric press brake must control both errors simultaneously.
Why Two Identical Drives Can Move Differently
Even when two servo motors, two ball screws, and their control parameters are identical, the actual loads acting on the two axes are not necessarily equal.
A few operating conditions can lead to differences between Y1 and Y2:
• An off-center workpiece can create an unbalanced load between the two sides of the ram.
• Tools that are not equally loaded can create differences in the force distribution along the tooling, which in turn can create unequal resistance.
• If there is more friction along one guideway, more torque may be required along the commanded motion.
• Differences along the mechanical transmission can create variations in the drive response.
Those conditions can be more pronounced during changes in speed and the application of a load. Differences in the two synchronized axes can become evident during rapid changes in speed. Differences in rotational inertia and stiffness of the transmission, and disturbance torque can be the reason for the differences.
For these reasons, dual-axis synchronization can't depend only on position commands. The control system needs to monitor the actual motion of both axes.
Motor encoders can give feedback on motor shaft position, but the mechanical transmission between the motor and ram includes reduction units, couplings, ball screws and other structures and linkages.
A full closed-loop control configuration using ram-side position feedback allows the actual displacement of the driven component to be measured directly and incorporated into the position control loop.
Learn more about linear scale feedback for Y1 and Y2.
Command, Master-Slave, and Cross-Coupled Control
Common coordination strategies for dual-axis motion systems include command control, master-slave control, and cross-coupled control. Their principal difference lies in how the two axes use motion information from each other.
1. Command Control
In command control, Y1 and Y2 receive a common reference trajectory, and each axis independently follows the commanded position.
This configuration has a relatively straightforward control structure. However, when one axis experiences a disturbance, the other axis generally does not actively adjust its motion in response to the positional difference between them.
Consequently, independent trajectory tracking alone does not necessarily guarantee minimum synchronization error under unequal loading conditions.
2. Master-Slave Control
One axis is identified as the master, and the other follows the master's motion as a slave.
This arrangement establishes a tracking relationship, but the response of the slave axis to the motion of the master is influenced by the characteristics of the motion of the master and the dynamics of signal transmission.
The two axes therefore do not operate under a fully symmetrical coordination relationship.
3. Cross-Coupled Control
Cross-coupled control compares the actual positions of Y1 and Y2 and feeds the resulting synchronization error back into both control channels.
When one axis falls behind because of a load disturbance, the controller does more than correct that axis's tracking error relative to the reference trajectory. It also coordinates the control outputs of both axes to reduce their relative positional difference.
The objective is not simply to make the lagging axis catch up as quickly as possible. Instead, the controller must balance individual trajectory tracking with dual-axis synchronization.
Synchronization Is Not the Same as Bend Accuracy
Good Y1/Y2 synchronization implies that the two sides of the ram move together and helps maintain alignment between the two ram ends.
However, this does not guarantee that the two ends of the workpiece will have the same bending angle.
There are a number of reasons for variations in the final bending angles including:
• Differences in the thickness of the sheet material
• Direction of the rolling of the sheet material and the anisotropic nature of some materials
• Elastic springback of the material
• Tooling, alignment and condition of the bending dies
• Deflection of the machine frame
• Crowning and deflection compensation
• Support conditions of the workpiece
Synchronization of the two ends of the ram is a function of the mechanical design and control of the bending machine. The bending angle is governed by the properties of the material, the tooling and the machine structure and the process parameters.
During machine acceptance tests, these two aspects should be checked separately.
At the control level, check actual Y1/Y2 position readings, synchronization alarms, position feedback, and the permissible off-center loading limits.
At the process level, do repeated trial bends with the actual production material, tooling and workpieces and check the bend angles and other measurements for repeatability and consistency.
How to Evaluate Y1/Y2 Synchronization Before Buying
A supplier's quoted "synchronization accuracy" value is insufficient without test conditions clearly stated.
Figures from different manufacturers are difficult to compare without the disclosure of the conditions under which the measurements were made, including load conditions, ram speed, ram stroke range and testing method.
While reviewing an electric press brake, buyers should ask the supplier the following questions:
1. Where are the actual Y1 and Y2 positions measured? Is position feedback obtained from the motor shafts or from each side of the ram?
2. Does each side of the ram have independent position feedback? Is each side measured by a separate feedback device?
3. Does the control system monitor both tracking error and synchronization error? Can it distinguish individual axis tracking deviations from the positional difference between the two axes?
4. How is synchronization error limited throughout the motion cycle? What control measures apply during rapid approach, bending, dwell, and return strokes?
5. What happens when the permissible synchronization error is exceeded? Does the controller raise an alarm? Is the motion speed reduced or is a controlled stop initiated?
6. How is permissible off-center loading defined? Under which loading and operating conditions and parameters was the limit established?
7. Can service personnel access diagnostic information? Is the actual position of Y1/Y2, alarm history and position feedback information available for troubleshooting?
If production involves off-center bending or multiple tooling stations, document those loading conditions in the technical specification and confirm the applicable limits with the supplier.
A dual-servo drive configuration should not be assumed to tolerate arbitrary eccentric loading at any position along the ram.
For a closer look at these deviations, see our guide to press brake Y1/Y2 synchronization errors.
Final Takeaway
The fundamental principle of Y1/Y2 synchronization is not simply to send identical commands to two servo motors. It is to measure the actual positions of both sides of the ram independently and continuously adjust the two drives based on tracking error and synchronization error.
The driving force comes from a dual-drive mechanism, position feedback is provided by an independent position feedback mechanism for both axes, and motion is coordinated by a synchronization control algorithm. This combination meets the requirements of a complete dual-axis synchronization system.
To see if this configuration meets your requirements, check out the JS RAGOS Servo Electric Press Brake.
In addition, you may send us your material grade, sheet thickness, bending length, part drawings and expected unbalanced load conditions for technical evaluation. Final machine selection should be based on representative part trials and agreed technical specifications.
Frequently Asked Questions
Q1: Are Y1 and Y2 the Two Servo Motors?
Not exactly. Y1 and Y2 refer to the controlled position axes on the left and right sides of the ram. Each axis typically has its own servo drive system and position feedback. These designations refer to the controlled ram positions rather than the servo motors themselves.
Q2: Does Y1/Y2 Synchronization Guarantee the Same Bend Angle?
No. Y1/Y2 synchronization primarily maintains coordinated movement and ram parallelism between the two sides of the ram. Material properties, springback, tooling conditions, machine frame deflection, and compensation settings can still affect the final bending angle.
Q3: Why Does a Dual-Drive Press Brake Need Two Position Signals?
The controller requires independent position feedback from both sides of the ram to calculate the synchronization error between Y1 and Y2. A single position measurement cannot fully determine whether both ends of the ram are moving synchronously.
Q4: Is Motor Encoder Feedback Enough for Ram Synchronization?
Motor encoders measure motor shaft motion but cannot directly detect all positional deviations introduced by the mechanical transmission between the motor and ram. To incorporate actual ram displacement into full closed-loop control, additional ram-side position feedback is typically required. The specific feedback configuration should be verified against the machine design and manufacturer's technical documentation.
The control research referenced herein compared these strategies by means of mathematical modeling and combined mechanical-electrical simulation. The virtual prototype was designed to allow the introduction of a one-sided unbalanced load to assess synchronization responses to case disturbed operating conditions.
The simulation results illustrate the rationale for the control and response function behaviors. However, they cannot serve as proof for JS RAGOS equipment synchronization accuracy nor replace testing of the physical machines.